return to home page Computational Chemistry Comparison and Benchmark DataBase Release 22 (May 2022) Standard Reference Database 101 National Institute of Standards and Technology
You are here: Comparisons > Vibrations > Vibrations > 2 calculations

Compare vibrational frequencies for two calculations for H2OH2O (water dimer)


A = HF/6-31G*
B = MP2/6-31G*

scale factors=0.8985, 0.943
  symmetry   frequency (cm-1)   reduced mass (amu)   IR Intensity (km mol-1)   Raman Activity (Å4/u)
mode number A B   A B diff. ratio   A B diff. ratio   A B diff. ratio   A B diff. ratio
1 A' A'   3740 3662 77.6 1.021   1.079 1.076 0.003 1.003   113.23 88.95 24.28 1.273          
2 A A'   3653 3547 105.6 1.030   1.046 1.045 0.001 1.001   30.15 15.75 14.40 1.914          
3 A' A'   3620 3496 124.0 1.035   1.049 1.051 -0.001 0.999   185.05 216.76 -31.70 0.854          
4 A A'   1665 1666 -1.6 0.999   1.078 1.078 0.000 1.000   104.02 89.15 14.87 1.167          
5 A' A'   1639 1634 5.2 1.003   1.082 1.082 0.000 1.000   114.69 87.56 27.14 1.310          
6 A A'   345 412 -67.4 0.836   1.102 1.081 0.021 1.020   95.22 40.27 54.95 2.365          
7 A' A'   163 202 -38.7 0.808   3.492 3.129 0.363 1.116   116.84 171.24 -54.40 0.682          
8 A A'   122 136 -13.8 0.899   1.275 1.343 -0.069 0.949   262.39 262.02 0.37 1.001          
9 A" A"   3755 3672 83.4 1.023   1.083 1.081 0.002 1.001   89.95 67.57 22.38 1.331          
10 A A"   556 637 -81.0 0.873   1.046 1.042 0.005 1.004   217.41 162.80 54.61 1.335          
11 A" A"   127 150 -23.0 0.847   1.068 1.072 -0.003 0.997   157.19 186.08 -28.89 0.845          
12 A A"   104 85 19.1 1.224   1.024 1.018 0.007 1.006   62.58 47.82 14.76 1.309          
scaled by     0.8985 0.943
19 08 20 15 07

See section III.C.1 List or set vibrational scaling factors to change the scale factors used here.
See section III.C.2 Calculate a vibrational scaling factor for a given set of molecules to determine the least squares best scaling factor.