return to home page

IV.C.1. (XIII.D.1.)

Compare vibrational frequencies in CCCBDB for H2OH2O (water dimer)

BLYP/6-31G**

Frequency in cm-1
  Calculated   Experimental
Mode Number Symmetry Frequency diff Symmetry Frequency Comment
1 A' 3693 -42 A' 3735  
2 A' 3611 -49 A' 3660  
3 A' 3493 -108 A' 3601  
4 A' 1652 36 A' 1616  
5 A' 1623 24 A' 1599  
6 A' 460 149 A' 311  
7 A' 224 81 A' 143  
8 A' 124 21 A' 103  
9 A" 3715 -30 A" 3745  
10 A" 661 138 A" 523  
11 A" 182 74 A" 108  
12 A" 113i -201 A" 88  
The calculated vibrational frequencies were scaled by 0.9923

See section XIII.C.3 List or set vibrational scaling factors to change the scale factors used here.
See section III.B.3.c Calculate a vibrational scaling factor for a set of molecules to determine the least squares best scaling factor.
See section III.B.3.b List of vibrational scaling factors and their uncertainties for information on where the above scaling factor is from.