return to home page

IV.C.1. (XIII.D.1.)

Compare vibrational frequencies in CCCBDB for SF4 (Sulfur tetrafluoride)

B3LYP/CEP-31G

Frequency in cm-1
  Calculated   Experimental
Mode Number Symmetry Frequency diff Symmetry Frequency Comment
1 A1 669 -223 A1 892  
2 A1 474 -84 A1 558  
3 A1 332 -200 A1 532  
4 A1 102 -126 A1 228  
5 A2 316 -96 A2 412  
6 B1 667 -197 B1 865 B1 B2 switched
7 B1 237 -116 B1 353 B1 B2 switched
8 B2 712 -18 B2 730 B1 B2 switched
9 B2 350 -125 B2 475 B1 B2 switched
The calculated vibrational frequencies were scaled by 0.9684

See section XIII.C.3 List or set vibrational scaling factors to change the scale factors used here.
See section III.B.3.c Calculate a vibrational scaling factor for a set of molecules to determine the least squares best scaling factor.
See section III.B.3.b List of vibrational scaling factors and their uncertainties for information on where the above scaling factor is from.