return to home page Computational Chemistry Comparison and Benchmark DataBase Release 21 (August 2020) Standard Reference Database 101 National Institute of Standards and Technology
You are here: Comparisons > Vibrations > Vibrations > 2 calculations

Compare vibrational frequencies for two calculations for H2CNCH (methyleneaminomethylene)


A = HF/6-31G*
B = MP2/6-31G*

scale factors=0.8985, 0.943 1.167 -0.218 -0.280 0.657
  symmetry   frequency (cm-1)   reduced mass (amu)   IR Intensity (km mol-1)
mode number A B   A B diff. ratio   A B diff. ratio   A B diff. ratio
1 A' A'   2984 3050 -66.1 0.978   1.051 1.047 0.003 1.003   0.82 5.87 0.140
2 A' A'   2884 3028 -143.9 0.952   1.088 1.104 -0.016 0.985   56.93 1.56 36.385
3 A' A'   1854 1955 -101.2 0.948   8.672 7.505 1.156   138.34 327.23 0.423
4 A' A'   1499 1438 61.5 1.043   1.271 1.261 0.009 1.007   0.21 2.36 0.090
5 A' A'   1169 1160 8.4 1.007   3.318 3.535 0.938   14.12 12.28 1.150
6 A' A'   1008 765 243.0 1.318   1.373 1.430 -0.057 0.960   303.21 549.43 0.552
7 A' A'   900 557 343.4 1.617   1.319 1.232 0.087 1.071   56.37 126.71 0.445
8 A' A'   462 470 -7.8 0.983   3.269 3.549 0.921   25.09 38.91 0.645
9 A" A"   3075 3163 -87.8 0.972   1.123 1.125 -0.002 0.998   14.76 1.52 9.718
10 A" A"   1148 1099 48.5 1.044   1.342 1.378 -0.036 0.974   14.06 4.98 2.822
11 A" A"   967 924 42.9 1.046   1.093 1.134 -0.041 0.964   7.44 9.57 0.777
12 A" A"   272 360 -88.0 0.756   3.735 3.078 1.214   6.28 4.05 1.550
scaled by     0.8985 0.943

See section III.C.1 List or set vibrational scaling factors to change the scale factors used here.
See section III.C.2 Calculate a vibrational scaling factor for a given set of molecules to determine the least squares best scaling factor.