Vibrational Frequencies calculated at MP2/6-31G(2df,p)
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
1867 |
1764 |
54.88 |
10.48 |
0.38 |
0.56 |
| 2 |
A' |
1407 |
1329 |
159.06 |
0.04 |
0.27 |
0.42 |
| 3 |
A' |
1275 |
1204 |
174.54 |
0.34 |
0.30 |
0.46 |
| 4 |
A' |
1097 |
1036 |
207.21 |
2.50 |
0.23 |
0.38 |
| 5 |
A' |
712 |
673 |
3.89 |
6.90 |
0.09 |
0.17 |
| 6 |
A' |
527 |
498 |
0.98 |
1.12 |
0.72 |
0.84 |
| 7 |
A' |
472 |
446 |
0.66 |
2.19 |
0.31 |
0.47 |
| 8 |
A' |
341 |
322 |
1.20 |
1.96 |
0.61 |
0.76 |
| 9 |
A' |
187 |
176 |
2.71 |
0.44 |
0.61 |
0.76 |
| 10 |
A" |
574 |
542 |
2.56 |
7.04 |
0.75 |
0.86 |
| 11 |
A" |
389 |
368 |
1.31 |
0.18 |
0.75 |
0.86 |
| 12 |
A" |
176 |
166 |
0.02 |
0.03 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 4511.1 cm
-1
Scaled (by 0.9445) Zero Point Vibrational Energy (zpe) 4260.7 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.