Computational Chemistry Comparison and Benchmark DataBase Release 22 (May 2022) Standard Reference Database 101 National Institute of Standards and Technology | |
You are here: Comparisons > Vibrations > Vibrations |
Calculated |   | Experimental | |||||||
---|---|---|---|---|---|---|---|---|---|
Mode Number | Symmetry | Frequency | Scaled Frequency |
Harm. diff |
Fund. diff |
Symmetry | Harmonic Frequency |
Fundamental Frequency |
Comment |
1 | Ag | 3142 | 3120 | 48 | Ag | 3072 | 1 | ||
2 | Ag | 1571 | 1560 | -14 | Ag | 1574 | 2 | ||
3 | Ag | 1158 | 1150 | -19 | Ag | 1169 | 3 | ||
4 | Ag | 1082 | 1075 | -21 | Ag | 1096 | 4 | ||
5 | Ag | 738 | 732 | -15 | Ag | 747 | 5 | ||
6 | Ag | 322 | 320 | -8 | Ag | 328 | 6 | ||
7 | Au | 937 | 931 | -20 | Au | 951 | 16 | ||
8 | Au | 407 | 404 | -1 | Au | 405 | 17 | ||
9 | B1g | 797 | 792 | -23 | B1g | 815 | 7 | ||
10 | B1u | 3127 | 3105 | 27 | B1u | 3078 | 18 | ||
11 | B1u | 1459 | 1449 | -28 | B1u | 1477 | 19 | ||
12 | B1u | 1072 | 1064 | -26 | B1u | 1090 | 20 | ||
13 | B1u | 998 | 992 | -23 | B1u | 1015 | 21 | ||
14 | B1u | 536 | 532 | -18 | B1u | 550 | 22 | ||
15 | B2g | 928 | 922 | -12 | B2g | 934 | 8 | ||
16 | B2g | 694 | 689 | 2 | B2g | 687 | 9 | ||
17 | B2g | 289 | 287 | -11 | B2g | 298 | 10 | ||
18 | B2u | 3140 | 3118 | 31 | B2u | 3087 | 23 | ||
19 | B2u | 1384 | 1375 | -19 | B2u | 1394 | 24 | ||
20 | B2u | 1322 | 1313 | 93 | B2u | 1220 | 25 | ||
21 | B2u | 1090 | 1082 | -25 | B2u | 1107 | 26 | ||
22 | B2u | 214 | 213 | -13 | B2u | 226 | 27 | ||
23 | B3g | 3128 | 3106 | 41 | B3g | 3065 | 11 | ||
24 | B3g | 1570 | 1559 | -15 | B3g | 1574 | 12 | ||
25 | B3g | 1271 | 1262 | -28 | B3g | 1290 | 13 | ||
26 | B3g | 617 | 613 | -13 | B3g | 626 | 14 | ||
27 | B3g | 342 | 340 | -10 | B3g | 350 | 15 | ||
28 | B3u | 810 | 804 | -15 | B3u | 819 | 28 | ||
29 | B3u | 479 | 476 | -9 | B3u | 485 | 29 | ||
30 | B3u | 99 | 98 | -24 | B3u | 122 | 30 |