Computational Chemistry Comparison and Benchmark DataBase Release 22 (May 2022) Standard Reference Database 101 National Institute of Standards and Technology | |
You are here: Comparisons > Vibrations > Vibrations |
Calculated |   | Experimental | |||||||
---|---|---|---|---|---|---|---|---|---|
Mode Number | Symmetry | Frequency | Scaled Frequency |
Harm. diff |
Fund. diff |
Symmetry | Harmonic Frequency |
Fundamental Frequency |
Comment |
1 | A1 | 1756 | 1697 | -12 | A1 | 1709 | |||
2 | A1 | 1153 | 1115 | -53 | A1 | 1168 | perturbed | ||
3 | A1 | 558 | 539 | -26 | A1 | 565 | |||
4 | A1 | 333 | 322 | -5 | A1 | 327 | |||
5 | A1 | 171 | 166 | -3 | A1 | 169 | |||
6 | A2 | 550 | 532 | A2 | solid phase 351 | ||||
7 | A2 | 146 | 141 | -9 | A2 | 150 | estimate | ||
8 | B1 | 344 | 333 | B1 | B1 and B2 switched, 533 questionable | ||||
9 | B2 | 1197 | 1157 | -52 | B2 | 1209 | B1 and B2 switched | ||
10 | B2 | 947 | 915 | -43 | B2 | 958 | B1 and B2 switched, perturbed | ||
11 | B2 | 429 | 415 | -16 | B2 | 431 | B1 and B2 switched | ||
12 | B2 | 415 | 401 | -14 | B2 | 415 | B1 and B2 switched |