Vibrational Frequencies calculated at MP2=FULL/aug-cc-pVTZ
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A |
3220 |
3064 |
0.08 |
70.43 |
0.19 |
0.31 |
2 |
A |
1347 |
1282 |
10.67 |
3.27 |
0.47 |
0.64 |
3 |
A |
1259 |
1198 |
59.74 |
2.02 |
0.36 |
0.53 |
4 |
A |
1103 |
1049 |
171.24 |
2.18 |
0.69 |
0.82 |
5 |
A |
820 |
781 |
180.96 |
3.25 |
0.66 |
0.79 |
6 |
A |
693 |
659 |
39.01 |
12.66 |
0.07 |
0.12 |
7 |
A |
437 |
416 |
0.64 |
4.16 |
0.14 |
0.24 |
8 |
A |
325 |
309 |
0.21 |
2.17 |
0.42 |
0.59 |
9 |
A |
233 |
221 |
0.00 |
2.48 |
0.39 |
0.56 |
Unscaled Zero Point Vibrational Energy (zpe) 4718.3 cm
-1
Scaled (by 0.9514) Zero Point Vibrational Energy (zpe) 4488.9 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.