Jump to
S1C2
Energy calculated at MP2=FULL/TZVP
| hartrees |
Energy at 0K | -1194.256795 |
Energy at 298.15K | -1194.259202 |
HF Energy | -1193.766551 |
Nuclear repulsion energy | 194.580851 |
The energy at 298.15K was derived from the energy at 0K
and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at MP2=FULL/TZVP
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A |
2749 |
2619 |
0.22 |
|
|
|
2 |
A |
901 |
859 |
0.27 |
|
|
|
3 |
A |
504 |
480 |
0.71 |
|
|
|
4 |
A |
315 |
300 |
27.34 |
|
|
|
5 |
A |
209 |
199 |
0.00 |
|
|
|
6 |
B |
2748 |
2618 |
5.10 |
|
|
|
7 |
B |
888 |
846 |
9.46 |
|
|
|
8 |
B |
505 |
481 |
23.57 |
|
|
|
9 |
B |
344 |
328 |
21.24 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 4581.2 cm
-1
Scaled (by 0.9527) Zero Point Vibrational Energy (zpe) 4364.5 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.
Geometric Data calculated at MP2=FULL/TZVP
Point Group is C2
Cartesians (Å)
Atom |
x (Å) |
y (Å) |
z (Å) |
S1 |
0.000 |
0.000 |
0.851 |
S2 |
0.000 |
1.671 |
-0.389 |
S3 |
0.000 |
-1.671 |
-0.389 |
H4 |
-1.324 |
1.752 |
-0.588 |
H5 |
1.324 |
-1.752 |
-0.588 |
Atom - Atom Distances (Å)
|
S1 |
S2 |
S3 |
H4 |
H5 |
S1 | | 2.0804 | 2.0804 | 2.6252 | 2.6252 |
S2 | 2.0804 | | 3.3413 | 1.3416 | 3.6750 | S3 | 2.0804 | 3.3413 | | 3.6750 | 1.3416 | H4 | 2.6252 | 1.3416 | 3.6750 | | 4.3919 | H5 | 2.6252 | 3.6750 | 1.3416 | 4.3919 | |
More geometry information
Calculated Bond Angles
atom1 |
atom2 |
atom3 |
angle |
|
atom1 |
atom2 |
atom3 |
angle |
S1 |
S2 |
H4 |
97.864 |
|
S1 |
S3 |
H5 |
97.864 |
S2 |
S1 |
S3 |
106.848 |
|
Electronic energy levels
Charges, Dipole, Quadrupole and Polarizability
Jump to
S1C1
Energy calculated at MP2=FULL/TZVP
| hartrees |
Energy at 0K | -1194.256366 |
Energy at 298.15K | -1194.258781 |
HF Energy | -1193.766028 |
Nuclear repulsion energy | 194.584587 |
The energy at 298.15K was derived from the energy at 0K
and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at MP2=FULL/TZVP
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A' |
2742 |
2613 |
9.34 |
|
|
|
2 |
A' |
904 |
861 |
5.36 |
|
|
|
3 |
A' |
504 |
480 |
0.66 |
|
|
|
4 |
A' |
344 |
328 |
21.05 |
|
|
|
5 |
A' |
210 |
200 |
0.12 |
|
|
|
6 |
A" |
2745 |
2615 |
0.13 |
|
|
|
7 |
A" |
894 |
852 |
5.84 |
|
|
|
8 |
A" |
505 |
481 |
26.15 |
|
|
|
9 |
A" |
318 |
303 |
12.04 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 4582.8 cm
-1
Scaled (by 0.9527) Zero Point Vibrational Energy (zpe) 4366.1 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.
Geometric Data calculated at MP2=FULL/TZVP
Point Group is Cs
Cartesians (Å)
Atom |
x (Å) |
y (Å) |
z (Å) |
S1 |
-0.053 |
0.849 |
0.000 |
S2 |
-0.053 |
-0.392 |
1.670 |
S3 |
-0.053 |
-0.392 |
-1.670 |
H4 |
1.276 |
-0.523 |
1.799 |
H5 |
1.276 |
-0.523 |
-1.799 |
Atom - Atom Distances (Å)
|
S1 |
S2 |
S3 |
H4 |
H5 |
S1 | | 2.0802 | 2.0802 | 2.6242 | 2.6242 |
S2 | 2.0802 | | 3.3398 | 1.3420 | 3.7173 | S3 | 2.0802 | 3.3398 | | 3.7173 | 1.3420 | H4 | 2.6242 | 1.3420 | 3.7173 | | 3.5981 | H5 | 2.6242 | 3.7173 | 1.3420 | 3.5981 | |
More geometry information
Calculated Bond Angles
atom1 |
atom2 |
atom3 |
angle |
|
atom1 |
atom2 |
atom3 |
angle |
S1 |
S2 |
H4 |
97.805 |
|
S1 |
S3 |
H5 |
97.805 |
S2 |
S1 |
S3 |
106.794 |
|
Electronic energy levels
Charges, Dipole, Quadrupole and Polarizability