Vibrational Frequencies calculated at MP2/cc-pVDZ
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A |
3197 |
3045 |
6.09 |
82.79 |
0.24 |
0.38 |
2 |
A |
1343 |
1279 |
20.55 |
4.95 |
0.75 |
0.86 |
3 |
A |
1243 |
1184 |
78.81 |
3.57 |
0.67 |
0.80 |
4 |
A |
1127 |
1073 |
194.96 |
1.30 |
0.74 |
0.85 |
5 |
A |
806 |
768 |
195.81 |
4.13 |
0.64 |
0.78 |
6 |
A |
675 |
643 |
53.53 |
9.33 |
0.16 |
0.28 |
7 |
A |
432 |
411 |
1.20 |
4.24 |
0.30 |
0.46 |
8 |
A |
320 |
305 |
0.08 |
3.11 |
0.56 |
0.71 |
9 |
A |
231 |
220 |
0.06 |
5.04 |
0.55 |
0.71 |
Unscaled Zero Point Vibrational Energy (zpe) 4685.7 cm
-1
Scaled (by 0.9525) Zero Point Vibrational Energy (zpe) 4463.2 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.