19 02 11 15 45

Calculated frequencies that differ from experiment by more than 400 cm-1 or have a ratio with experiment outside of 0.7 to 1.2 are listed

Calculated vibrational frequencies ("theory" in table) are calculated at CISD/aug-cc-pCVTZ
Calculated values were scaled by 1.

Species Name mode int rot Symmetry Experiment Theory difference ratio
NS Mononitrogen monosulfide 1 Σ 1204 1621 417 0.743
SiC2 Silicon dicarbide 3 B2 196 -110 -306 -1.792
HNO Nitrosyl hydride 1 A' 2684 3125 441 0.859
OPCl Phosphorus oxychloride 2 A' 308 526 218 0.585
OPCl Phosphorus oxychloride 3 A' 492 330 -162 1.492