Computational Chemistry Comparison and Benchmark DataBase Release 22 (May 2022) Standard Reference Database 101 National Institute of Standards and Technology | |
|
|
You are here: Calculated > Vibrations > Bad Calculations > Bad vib. Calc. vs exp. OR Resources > Bad Calculations > Vibrations > Bad vib. Calc. vs exp. |
Calculated frequencies that differ from experiment by more than 400 cm-1 or have a ratio with experiment outside of 0.7 to 1.2 are listed
Calculated vibrational frequencies ("theory" in table) are calculated at
B3PW91/CEP-121G
Calculated values were scaled by 0.9573.
Species | Name | mode | int rot | Symmetry | Experiment | Theory | difference | ratio |
---|---|---|---|---|---|---|---|---|
SO2 | Sulfur dioxide | 1 | A1 | 1151 | 857 | -294 | 1.343 | |
SO2 | Sulfur dioxide | 2 | A1 | 518 | 366 | -152 | 1.416 | |
SO2 | Sulfur dioxide | 3 | B2 | 1362 | 934 | -428 | 1.459 | |
NH3 | Ammonia | 2 | torsion | A1 | 950 | 521 | -429 | 1.824 |