Computational Chemistry Comparison and Benchmark DataBase Release 22 (May 2022) Standard Reference Database 101 National Institute of Standards and Technology | |
|
|
You are here: Calculated > Vibrations > Bad Calculations > Bad vib. Calc. vs exp. OR Resources > Bad Calculations > Vibrations > Bad vib. Calc. vs exp. |
Calculated frequencies that differ from experiment by more than 400 cm-1 or have a ratio with experiment outside of 0.7 to 1.2 are listed
Calculated vibrational frequencies ("theory" in table) are calculated at
B2PLYP/CEP-31G
Calculated values were scaled by 1.
Species | Name | mode | int rot | Symmetry | Experiment | Theory | difference | ratio |
---|---|---|---|---|---|---|---|---|
LiH | Lithium Hydride | 1 | Σ | 1360 | -1264 | -2623 | -1.076 | |
NH3 | Ammonia | 2 | torsion | A1 | 950 | 557 | -393 | 1.707 |