return to home page Computational Chemistry Comparison and Benchmark DataBase Release 22 (May 2022) Standard Reference Database 101 National Institute of Standards and Technology
You are here: Calculated > Energy > Optimized > Energy

All results from a given calculation for CO (Carbon monoxide)

using model chemistry: G3

19 10 17 12 22

States and conformations

State Conformation minimum conformation conformer description state description
1 1 yes C*V 1Σ
2 1 yes C*V 3Π

State 1 (1Σ)

Jump to S2C1
Energy calculated at G3
 hartrees
Energy at 0K-113.267369
Energy at 298.15K-113.264064
HF Energy-112.737877
Nuclear repulsion energy22.804741
The energy at 298.15K was derived from the energy at 0K and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at HF/6-31G*
Mode Number Symmetry Frequency
(cm-1)
Scaled Frequency
(cm-1)
IR Intensities
(km mol-1)
Raman Act
4/u)
Dep P Dep U
1 Σ 2439 2298 137.91      

Unscaled Zero Point Vibrational Energy (zpe) 1219.3 cm-1
Scaled (by 0.9422) Zero Point Vibrational Energy (zpe) 1148.8 cm-1
See section III.C.1 List or set vibrational scaling factors to change the scale factors used here.
See section III.C.2 Calculate a vibrational scaling factor for a given set of molecules to determine the least squares best scaling factor.
Rotational Constants (cm-1) from geometry optimized at MP2=FULL/6-31G*
B
1.85841

See section I.F.4 to change rotational constant units
Geometric Data calculated at MP2=FULL/6-31G*

Point Group is C∞v

Cartesians (Å)
Atom x (Å) y (Å) z (Å)
C1 0.000 0.000 -0.656
O2 0.000 0.000 0.492

Atom - Atom Distances (Å)
  C1 O2
C11.1488
O21.1488

picture of Carbon monoxide state 1 conformation 1
More geometry information
Electronic energy levels

Electronic state

Charges, Dipole, Quadrupole and Polarizability

State 2 (3Π)

Jump to S1C1
Energy calculated at G3
 hartrees
Energy at 0K-113.047409
Energy at 298.15K-113.044100
HF Energy-112.547173
Nuclear repulsion energy21.230185
The energy at 298.15K was derived from the energy at 0K and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at HF/6-31G*
Mode Number Symmetry Frequency
(cm-1)
Scaled Frequency
(cm-1)
IR Intensities
(km mol-1)
Raman Act
4/u)
Dep P Dep U
1 Σ 1728 1628 1.74      

Unscaled Zero Point Vibrational Energy (zpe) 863.9 cm-1
Scaled (by 0.9422) Zero Point Vibrational Energy (zpe) 813.9 cm-1
See section III.C.1 List or set vibrational scaling factors to change the scale factors used here.
See section III.C.2 Calculate a vibrational scaling factor for a given set of molecules to determine the least squares best scaling factor.
Rotational Constants (cm-1) from geometry optimized at MP2=FULL/6-31G*
B
1.77632

See section I.F.4 to change rotational constant units
Geometric Data calculated at MP2=FULL/6-31G*

Point Group is C∞v

Cartesians (Å)
Atom x (Å) y (Å) z (Å)
C1 0.000 0.000 -0.672
O2 0.000 0.000 0.504

Atom - Atom Distances (Å)
  C1 O2
C11.1765
O21.1765

picture of Carbon monoxide state 2 conformation 1
More geometry information
Electronic energy levels

Electronic state

Charges, Dipole, Quadrupole and Polarizability