Vibrational Frequencies calculated at MP2=FULL/6-31G*
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3269 |
3080 |
20.09 |
|
|
|
| 2 |
A' |
1444 |
1360 |
73.66 |
|
|
|
| 3 |
A' |
1194 |
1125 |
202.94 |
|
|
|
| 4 |
A' |
924 |
870 |
181.95 |
|
|
|
| 5 |
A' |
826 |
779 |
72.45 |
|
|
|
| 6 |
A' |
558 |
526 |
102.74 |
|
|
|
| 7 |
A' |
469 |
442 |
55.72 |
|
|
|
| 8 |
A' |
372 |
351 |
43.70 |
|
|
|
| 9 |
A' |
261 |
246 |
0.38 |
|
|
|
| 10 |
A" |
3380 |
3185 |
9.20 |
|
|
|
| 11 |
A" |
1029 |
970 |
223.14 |
|
|
|
| 12 |
A" |
841 |
793 |
0.99 |
|
|
|
| 13 |
A" |
458 |
431 |
0.00 |
|
|
|
| 14 |
A" |
368 |
347 |
16.96 |
|
|
|
| 15 |
A" |
201 |
189 |
0.84 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 7797.1 cm
-1
Scaled (by 0.9422) Zero Point Vibrational Energy (zpe) 7346.5 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.