Vibrational Frequencies calculated at MP2=FULL/6-311+G(3df,2p)
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3264 |
3077 |
1.95 |
73.26 |
0.59 |
0.74 |
| 2 |
A' |
3133 |
2953 |
12.66 |
94.33 |
0.09 |
0.17 |
| 3 |
A' |
2192 |
2066 |
13.61 |
166.54 |
0.23 |
0.37 |
| 4 |
A' |
1682 |
1586 |
13.06 |
35.33 |
0.15 |
0.27 |
| 5 |
A' |
1512 |
1425 |
14.10 |
21.87 |
0.36 |
0.53 |
| 6 |
A' |
1238 |
1167 |
9.77 |
2.20 |
0.73 |
0.85 |
| 7 |
A' |
956 |
901 |
6.85 |
2.11 |
0.04 |
0.08 |
| 8 |
A' |
620 |
585 |
3.18 |
2.52 |
0.13 |
0.22 |
| 9 |
A' |
250 |
235 |
6.22 |
6.85 |
0.48 |
0.65 |
| 10 |
A" |
1096 |
1033 |
20.02 |
0.55 |
0.75 |
0.86 |
| 11 |
A" |
782 |
737 |
0.68 |
1.67 |
0.75 |
0.86 |
| 12 |
A" |
367 |
346 |
8.53 |
0.13 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 8544.7 cm
-1
Scaled (by 0.9427) Zero Point Vibrational Energy (zpe) 8055.1 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.