Vibrational Frequencies calculated at MP2=FULL/aug-cc-pVDZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3267 |
3166 |
2.94 |
77.04 |
0.58 |
0.73 |
| 2 |
A' |
3127 |
3031 |
13.61 |
104.30 |
0.09 |
0.16 |
| 3 |
A' |
2145 |
2079 |
8.70 |
165.31 |
0.22 |
0.37 |
| 4 |
A' |
1658 |
1607 |
9.51 |
32.03 |
0.15 |
0.26 |
| 5 |
A' |
1496 |
1450 |
12.29 |
24.40 |
0.33 |
0.50 |
| 6 |
A' |
1222 |
1184 |
8.96 |
1.93 |
0.74 |
0.85 |
| 7 |
A' |
933 |
905 |
5.84 |
2.29 |
0.02 |
0.05 |
| 8 |
A' |
609 |
590 |
2.03 |
2.54 |
0.11 |
0.20 |
| 9 |
A' |
244 |
236 |
5.98 |
6.83 |
0.48 |
0.65 |
| 10 |
A" |
1083 |
1049 |
20.84 |
0.45 |
0.75 |
0.86 |
| 11 |
A" |
768 |
744 |
0.34 |
1.58 |
0.75 |
0.86 |
| 12 |
A" |
348 |
337 |
7.40 |
0.10 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 8449.6 cm
-1
Scaled (by 0.9692) Zero Point Vibrational Energy (zpe) 8189.3 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.