Vibrational Frequencies calculated at B2PLYP=FULL/aug-cc-pVTZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3163 |
3034 |
5.76 |
54.22 |
0.75 |
0.86 |
| 2 |
A' |
3082 |
2956 |
22.60 |
156.86 |
0.00 |
0.01 |
| 3 |
A' |
2717 |
2607 |
2.09 |
127.15 |
0.21 |
0.35 |
| 4 |
A' |
1507 |
1446 |
7.28 |
4.10 |
0.75 |
0.86 |
| 5 |
A' |
1370 |
1314 |
5.86 |
0.43 |
0.05 |
0.09 |
| 6 |
A' |
1105 |
1060 |
10.14 |
1.79 |
0.65 |
0.79 |
| 7 |
A' |
805 |
772 |
0.34 |
6.44 |
0.19 |
0.32 |
| 8 |
A' |
714 |
685 |
1.70 |
16.17 |
0.18 |
0.30 |
| 9 |
A" |
3165 |
3037 |
5.18 |
64.03 |
0.75 |
0.86 |
| 10 |
A" |
1493 |
1433 |
4.36 |
3.96 |
0.75 |
0.86 |
| 11 |
A" |
984 |
944 |
4.03 |
0.07 |
0.75 |
0.86 |
| 12 |
A" |
233 |
224 |
10.73 |
0.23 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 10168.7 cm
-1
Scaled (by 0.9594) Zero Point Vibrational Energy (zpe) 9755.9 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.