Vibrational Frequencies calculated at MP2=FULL/aug-cc-pVTZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3315 |
3154 |
0.35 |
32.40 |
0.66 |
0.79 |
| 2 |
A' |
3263 |
3105 |
3.78 |
140.70 |
0.16 |
0.27 |
| 3 |
A' |
3222 |
3065 |
2.39 |
36.53 |
0.14 |
0.25 |
| 4 |
A' |
1717 |
1634 |
106.12 |
30.07 |
0.02 |
0.04 |
| 5 |
A' |
1422 |
1353 |
6.38 |
5.12 |
0.29 |
0.45 |
| 6 |
A' |
1337 |
1272 |
1.65 |
12.87 |
0.37 |
0.54 |
| 7 |
A' |
1181 |
1123 |
96.96 |
2.21 |
0.18 |
0.30 |
| 8 |
A' |
942 |
896 |
38.17 |
4.24 |
0.29 |
0.45 |
| 9 |
A' |
480 |
456 |
4.08 |
1.26 |
0.52 |
0.69 |
| 10 |
A" |
970 |
923 |
38.63 |
0.55 |
0.75 |
0.86 |
| 11 |
A" |
883 |
840 |
41.82 |
3.15 |
0.75 |
0.86 |
| 12 |
A" |
739 |
703 |
3.46 |
0.35 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 9735.7 cm
-1
Scaled (by 0.9514) Zero Point Vibrational Energy (zpe) 9262.5 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.