Vibrational Frequencies calculated at MP2=FULL/6-31G(2df,p)
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A1 |
3231 |
3036 |
38.68 |
150.01 |
0.12 |
0.21 |
| 2 |
A1 |
1865 |
1753 |
295.25 |
0.76 |
0.35 |
0.52 |
| 3 |
A1 |
1394 |
1311 |
1.99 |
14.46 |
0.57 |
0.73 |
| 4 |
A1 |
875 |
822 |
5.79 |
27.38 |
0.23 |
0.38 |
| 5 |
B1 |
684 |
643 |
78.12 |
0.42 |
0.75 |
0.86 |
| 6 |
B1 |
453 |
426 |
2.80 |
0.80 |
0.75 |
0.86 |
| 7 |
B2 |
3330 |
3130 |
7.72 |
87.58 |
0.75 |
0.86 |
| 8 |
B2 |
947 |
890 |
0.01 |
0.16 |
0.75 |
0.86 |
| 9 |
B2 |
376 |
353 |
1.81 |
0.08 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 6576.6 cm
-1
Scaled (by 0.9399) Zero Point Vibrational Energy (zpe) 6181.4 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.