Vibrational Frequencies calculated at MP2=FULL/6-31G(2df,p)
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3269 |
3073 |
0.96 |
|
|
|
| 2 |
A' |
3140 |
2951 |
0.03 |
|
|
|
| 3 |
A' |
1923 |
1808 |
213.78 |
|
|
|
| 4 |
A' |
1507 |
1417 |
12.29 |
|
|
|
| 5 |
A' |
1429 |
1343 |
45.41 |
|
|
|
| 6 |
A' |
1254 |
1179 |
188.88 |
|
|
|
| 7 |
A' |
1033 |
971 |
26.38 |
|
|
|
| 8 |
A' |
879 |
826 |
36.28 |
|
|
|
| 9 |
A' |
611 |
574 |
19.52 |
|
|
|
| 10 |
A' |
416 |
391 |
0.02 |
|
|
|
| 11 |
A" |
3230 |
3036 |
0.12 |
|
|
|
| 12 |
A" |
1516 |
1425 |
7.67 |
|
|
|
| 13 |
A" |
1091 |
1025 |
9.38 |
|
|
|
| 14 |
A" |
591 |
556 |
4.62 |
|
|
|
| 15 |
A" |
148 |
139 |
0.11 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 11018.4 cm
-1
Scaled (by 0.9399) Zero Point Vibrational Energy (zpe) 10356.2 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.