Jump to
S1C2
Energy calculated at MP2=FULL/STO-3G
| | hartrees |
| Energy at 0K | -165.622208 |
| Energy at 298.15K | |
| HF Energy | -165.374995 |
| Nuclear repulsion energy | 57.537333 |
The energy at 298.15K was derived from the energy at 0K
and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at MP2=FULL/STO-3G
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
Σ |
3754 |
3337 |
306.68 |
43.79 |
0.28 |
0.44 |
| 2 |
Σ |
2277 |
2024 |
188.41 |
4.03 |
0.46 |
0.63 |
| 3 |
Σ |
1284 |
1142 |
6.11 |
23.74 |
0.28 |
0.44 |
| 4 |
Π |
477 |
424 |
1.59 |
0.05 |
0.75 |
0.86 |
| 4 |
Π |
477 |
424 |
1.59 |
0.05 |
0.75 |
0.86 |
| 5 |
Π |
701i |
624i |
63.02 |
0.75 |
0.75 |
0.86 |
| 5 |
Π |
701i |
624i |
63.02 |
0.75 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 3433.2 cm
-1
Scaled (by 0.8889) Zero Point Vibrational Energy (zpe) 3051.8 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.
Geometric Data calculated at MP2=FULL/STO-3G
Point Group is C∞v
Cartesians (Å)
| Atom |
x (Å) |
y (Å) |
z (Å) |
| O1 |
0.000 |
0.000 |
1.241 |
| N2 |
0.000 |
0.000 |
-0.016 |
| C3 |
0.000 |
0.000 |
-1.249 |
| H4 |
0.000 |
0.000 |
-2.324 |
Atom - Atom Distances (Å)
| |
O1 |
N2 |
C3 |
H4 |
| O1 | | 1.2572 | 2.4906 | 3.5650 |
N2 | 1.2572 | | 1.2334 | 2.3077 | C3 | 2.4906 | 1.2334 | | 1.0744 | H4 | 3.5650 | 2.3077 | 1.0744 | |
More geometry information
Calculated Bond Angles
| atom1 |
atom2 |
atom3 |
angle |
|
atom1 |
atom2 |
atom3 |
angle |
| O1 |
N2 |
C3 |
180.000 |
|
N2 |
C3 |
H4 |
180.000 |
Electronic energy levels
Charges, Dipole, Quadrupole and Polarizability
Jump to
S1C1
Energy calculated at MP2=FULL/STO-3G
| | hartrees |
| Energy at 0K | -165.627542 |
| Energy at 298.15K | -165.628429 |
| HF Energy | -165.372819 |
| Nuclear repulsion energy | 57.454527 |
The energy at 298.15K was derived from the energy at 0K
and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at MP2=FULL/STO-3G
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3661 |
3255 |
147.29 |
|
|
|
| 2 |
A' |
2498 |
2220 |
99.27 |
|
|
|
| 3 |
A' |
1344 |
1195 |
24.63 |
|
|
|
| 4 |
A' |
946 |
841 |
1.92 |
|
|
|
| 5 |
A' |
442 |
393 |
1.06 |
|
|
|
| 6 |
A" |
672 |
597 |
0.02 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 4781.1 cm
-1
Scaled (by 0.8889) Zero Point Vibrational Energy (zpe) 4249.9 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.
Geometric Data calculated at MP2=FULL/STO-3G
Point Group is Cs
Cartesians (Å)
| Atom |
x (Å) |
y (Å) |
z (Å) |
| O1 |
-1.199 |
-0.287 |
0.000 |
| N2 |
0.000 |
0.097 |
0.000 |
| C3 |
1.243 |
0.142 |
0.000 |
| H4 |
2.128 |
0.768 |
0.000 |
Atom - Atom Distances (Å)
| |
O1 |
N2 |
C3 |
H4 |
| O1 | | 1.2587 | 2.4793 | 3.4899 |
N2 | 1.2587 | | 1.2442 | 2.2312 | C3 | 2.4793 | 1.2442 | | 1.0840 | H4 | 3.4899 | 2.2312 | 1.0840 | |
More geometry information
Calculated Bond Angles
| atom1 |
atom2 |
atom3 |
angle |
|
atom1 |
atom2 |
atom3 |
angle |
| O1 |
N2 |
C3 |
164.270 |
|
N2 |
C3 |
H4 |
146.733 |
Electronic energy levels
Charges, Dipole, Quadrupole and Polarizability