Vibrational Frequencies calculated at MP2=FULL/6-311G**
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
1856 |
1761 |
56.44 |
11.54 |
0.31 |
0.47 |
| 2 |
A' |
1375 |
1304 |
185.78 |
0.12 |
0.39 |
0.56 |
| 3 |
A' |
1251 |
1187 |
205.54 |
0.52 |
0.38 |
0.55 |
| 4 |
A' |
1089 |
1033 |
249.68 |
2.20 |
0.17 |
0.29 |
| 5 |
A' |
709 |
672 |
2.94 |
6.41 |
0.14 |
0.25 |
| 6 |
A' |
526 |
499 |
1.15 |
1.77 |
0.72 |
0.84 |
| 7 |
A' |
474 |
449 |
0.75 |
2.30 |
0.44 |
0.61 |
| 8 |
A' |
348 |
330 |
1.51 |
2.52 |
0.65 |
0.79 |
| 9 |
A' |
193 |
183 |
3.25 |
0.61 |
0.67 |
0.81 |
| 10 |
A" |
575 |
546 |
3.51 |
10.30 |
0.75 |
0.86 |
| 11 |
A" |
388 |
368 |
1.25 |
0.55 |
0.75 |
0.86 |
| 12 |
A" |
175 |
166 |
0.09 |
0.10 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 4479.2 cm
-1
Scaled (by 0.9486) Zero Point Vibrational Energy (zpe) 4249.0 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.