Vibrational Frequencies calculated at MP2=FULL/cc-pVQZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3172 |
3036 |
2.61 |
|
|
|
| 2 |
A' |
1475 |
1411 |
0.08 |
|
|
|
| 3 |
A' |
1277 |
1222 |
45.81 |
|
|
|
| 4 |
A' |
790 |
756 |
86.03 |
|
|
|
| 5 |
A' |
658 |
629 |
16.97 |
|
|
|
| 6 |
A' |
235 |
225 |
0.22 |
|
|
|
| 7 |
A" |
3258 |
3118 |
1.66 |
|
|
|
| 8 |
A" |
1179 |
1129 |
0.01 |
|
|
|
| 9 |
A" |
878 |
841 |
2.52 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 6461.0 cm
-1
Scaled (by 0.9571) Zero Point Vibrational Energy (zpe) 6183.8 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.