Vibrational Frequencies calculated at HF/TZVP
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3300 |
2998 |
19.07 |
|
|
|
| 2 |
A' |
3198 |
2905 |
30.07 |
|
|
|
| 3 |
A' |
1621 |
1473 |
12.24 |
|
|
|
| 4 |
A' |
1595 |
1449 |
2.33 |
|
|
|
| 5 |
A' |
1337 |
1215 |
11.91 |
|
|
|
| 6 |
A' |
1269 |
1153 |
70.33 |
|
|
|
| 7 |
A' |
1055 |
959 |
32.09 |
|
|
|
| 8 |
A' |
534 |
485 |
4.91 |
|
|
|
| 9 |
A" |
3279 |
2979 |
34.60 |
|
|
|
| 10 |
A" |
1603 |
1457 |
6.65 |
|
|
|
| 11 |
A" |
1272 |
1155 |
2.54 |
|
|
|
| 12 |
A" |
187 |
170 |
1.27 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 10124.5 cm
-1
Scaled (by 0.9086) Zero Point Vibrational Energy (zpe) 9199.1 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.