Vibrational Frequencies calculated at B3LYP/TZVP
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3159 |
3050 |
8.50 |
|
|
|
| 2 |
A' |
3054 |
2948 |
13.03 |
|
|
|
| 3 |
A' |
1484 |
1433 |
9.98 |
|
|
|
| 4 |
A' |
1450 |
1400 |
1.15 |
|
|
|
| 5 |
A' |
1216 |
1173 |
7.49 |
|
|
|
| 6 |
A' |
1143 |
1103 |
3.91 |
|
|
|
| 7 |
A' |
909 |
878 |
13.34 |
|
|
|
| 8 |
A' |
489 |
472 |
6.65 |
|
|
|
| 9 |
A" |
3143 |
3035 |
13.16 |
|
|
|
| 10 |
A" |
1473 |
1422 |
9.71 |
|
|
|
| 11 |
A" |
1130 |
1091 |
0.48 |
|
|
|
| 12 |
A" |
141 |
136 |
0.22 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 9395.3 cm
-1
Scaled (by 0.9654) Zero Point Vibrational Energy (zpe) 9070.2 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.