Vibrational Frequencies calculated at CCSD=FULL/TZVP
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3288 |
3116 |
0.62 |
|
|
|
| 2 |
A' |
3217 |
3048 |
5.19 |
|
|
|
| 3 |
A' |
3114 |
2950 |
4.76 |
|
|
|
| 4 |
A' |
1658 |
1571 |
1.59 |
|
|
|
| 5 |
A' |
1427 |
1352 |
5.32 |
|
|
|
| 6 |
A' |
1094 |
1036 |
7.38 |
|
|
|
| 7 |
A' |
749 |
709 |
16.85 |
|
|
|
| 8 |
A" |
926 |
878 |
85.09 |
|
|
|
| 9 |
A" |
811 |
768 |
2.42 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 8141.4 cm
-1
Scaled (by 0.9475) Zero Point Vibrational Energy (zpe) 7714.0 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.