Vibrational Frequencies calculated at MP2/TZVP
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3342 |
3168 |
1.00 |
35.37 |
0.70 |
0.82 |
| 2 |
A' |
3272 |
3102 |
7.01 |
107.09 |
0.24 |
0.39 |
| 3 |
A' |
3231 |
3063 |
1.10 |
65.03 |
0.16 |
0.27 |
| 4 |
A' |
1717 |
1628 |
98.29 |
15.68 |
0.02 |
0.04 |
| 5 |
A' |
1438 |
1363 |
4.65 |
3.02 |
0.41 |
0.58 |
| 6 |
A' |
1361 |
1290 |
3.18 |
14.25 |
0.52 |
0.68 |
| 7 |
A' |
1183 |
1121 |
102.58 |
1.84 |
0.26 |
0.42 |
| 8 |
A' |
945 |
895 |
38.08 |
3.90 |
0.37 |
0.54 |
| 9 |
A' |
488 |
463 |
4.26 |
1.94 |
0.67 |
0.80 |
| 10 |
A" |
961 |
911 |
46.61 |
0.63 |
0.75 |
0.86 |
| 11 |
A" |
774 |
734 |
44.87 |
0.99 |
0.75 |
0.86 |
| 12 |
A" |
724 |
687 |
0.12 |
2.40 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 9717.9 cm
-1
Scaled (by 0.9479) Zero Point Vibrational Energy (zpe) 9211.6 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.