Vibrational Frequencies calculated at MP2/daug-cc-pVTZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3192 |
3192 |
0.07 |
70.96 |
0.18 |
0.31 |
| 2 |
A' |
1333 |
1333 |
11.03 |
4.08 |
0.37 |
0.54 |
| 3 |
A' |
1093 |
1093 |
164.76 |
2.86 |
0.55 |
0.71 |
| 4 |
A' |
648 |
648 |
20.02 |
12.46 |
0.05 |
0.09 |
| 5 |
A' |
369 |
369 |
0.21 |
5.07 |
0.10 |
0.18 |
| 6 |
A' |
177 |
177 |
0.01 |
2.25 |
0.35 |
0.52 |
| 7 |
A" |
1219 |
1219 |
71.04 |
1.29 |
0.75 |
0.86 |
| 8 |
A" |
751 |
751 |
167.23 |
3.67 |
0.75 |
0.86 |
| 9 |
A" |
304 |
304 |
0.16 |
1.44 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 4542.1 cm
-1
Scaled (by 1) Zero Point Vibrational Energy (zpe) 4542.1 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.