Vibrational Frequencies calculated at MP4/cc-pVDZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A |
3827 |
3700 |
|
|
|
|
| 2 |
A |
3144 |
3039 |
|
|
|
|
| 3 |
A |
3042 |
2941 |
|
|
|
|
| 4 |
A |
1532 |
1482 |
|
|
|
|
| 5 |
A |
1467 |
1418 |
|
|
|
|
| 6 |
A |
1417 |
1370 |
|
|
|
|
| 7 |
A |
1272 |
1230 |
|
|
|
|
| 8 |
A |
1165 |
1127 |
|
|
|
|
| 9 |
A |
1085 |
1049 |
|
|
|
|
| 10 |
A |
1038 |
1004 |
|
|
|
|
| 11 |
A |
550 |
532 |
|
|
|
|
| 12 |
A |
401 |
388 |
|
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 9969.8 cm
-1
Scaled (by 0.9669) Zero Point Vibrational Energy (zpe) 9639.8 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.