Vibrational Frequencies calculated at B2PLYP=FULL/cc-pVDZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3458 |
3314 |
0.67 |
220.54 |
0.31 |
0.48 |
| 2 |
A' |
3080 |
2952 |
33.24 |
131.50 |
0.39 |
0.56 |
| 3 |
A' |
2710 |
2598 |
0.32 |
109.05 |
0.27 |
0.43 |
| 4 |
A' |
1659 |
1590 |
144.04 |
12.40 |
0.23 |
0.37 |
| 5 |
A' |
1378 |
1321 |
26.83 |
5.12 |
0.11 |
0.20 |
| 6 |
A' |
1202 |
1152 |
28.98 |
13.96 |
0.59 |
0.74 |
| 7 |
A' |
927 |
889 |
43.42 |
5.34 |
0.51 |
0.67 |
| 8 |
A' |
709 |
679 |
66.68 |
4.85 |
0.24 |
0.38 |
| 9 |
A' |
424 |
406 |
15.68 |
3.46 |
0.44 |
0.61 |
| 10 |
A" |
1056 |
1012 |
2.87 |
0.54 |
0.75 |
0.86 |
| 11 |
A" |
732 |
701 |
64.82 |
3.58 |
0.75 |
0.86 |
| 12 |
A" |
400 |
383 |
36.69 |
4.86 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 8866.6 cm
-1
Scaled (by 0.9585) Zero Point Vibrational Energy (zpe) 8498.6 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.