Vibrational Frequencies calculated at MP2=FULL/cc-pVTZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3731 |
3542 |
72.21 |
52.95 |
0.07 |
0.13 |
| 2 |
A' |
1613 |
1532 |
87.48 |
4.48 |
0.65 |
0.78 |
| 3 |
A' |
965 |
916 |
53.31 |
8.00 |
0.41 |
0.58 |
| 4 |
A' |
787 |
747 |
128.83 |
7.38 |
0.17 |
0.29 |
| 5 |
A" |
3844 |
3649 |
200.74 |
19.10 |
0.75 |
0.86 |
| 6 |
A" |
932 |
885 |
0.05 |
3.39 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 5935.9 cm
-1
Scaled (by 0.9494) Zero Point Vibrational Energy (zpe) 5635.6 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.