Vibrational Frequencies calculated at B2PLYP=FULL/cc-pVTZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3181 |
3041 |
14.49 |
|
|
|
| 2 |
A' |
3074 |
2938 |
21.88 |
|
|
|
| 3 |
A' |
2987 |
2855 |
24.50 |
|
|
|
| 4 |
A' |
1502 |
1435 |
2.41 |
|
|
|
| 5 |
A' |
1487 |
1422 |
3.03 |
|
|
|
| 6 |
A' |
1415 |
1352 |
1.65 |
|
|
|
| 7 |
A' |
1076 |
1029 |
0.05 |
|
|
|
| 8 |
A' |
992 |
948 |
0.47 |
|
|
|
| 9 |
A' |
487 |
466 |
51.82 |
|
|
|
| 10 |
A" |
3278 |
3133 |
13.11 |
|
|
|
| 11 |
A" |
3117 |
2979 |
20.00 |
|
|
|
| 12 |
A" |
1500 |
1434 |
5.04 |
|
|
|
| 13 |
A" |
1209 |
1156 |
2.13 |
|
|
|
| 14 |
A" |
820 |
784 |
1.64 |
|
|
|
| 15 |
A" |
114 |
109 |
0.02 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 13119.2 cm
-1
Scaled (by 0.9558) Zero Point Vibrational Energy (zpe) 12539.4 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.