Vibrational Frequencies calculated at MP2=FULL/cc-pVTZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
1338 |
1270 |
315.56 |
|
|
|
| 2 |
A' |
1266 |
1202 |
350.27 |
|
|
|
| 3 |
A' |
1026 |
974 |
13.17 |
|
|
|
| 4 |
A' |
908 |
862 |
2.63 |
|
|
|
| 5 |
A' |
698 |
662 |
11.86 |
|
|
|
| 6 |
A' |
598 |
568 |
3.55 |
|
|
|
| 7 |
A' |
447 |
424 |
0.44 |
|
|
|
| 8 |
A' |
267 |
253 |
1.14 |
|
|
|
| 9 |
A" |
1295 |
1229 |
375.45 |
|
|
|
| 10 |
A" |
623 |
591 |
4.84 |
|
|
|
| 11 |
A" |
440 |
418 |
0.01 |
|
|
|
| 12 |
A" |
146 |
138 |
0.02 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 4524.8 cm
-1
Scaled (by 0.9494) Zero Point Vibrational Energy (zpe) 4295.8 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.