Vibrational Frequencies calculated at MP2=FULL/cc-pVTZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
3513 |
3335 |
6.34 |
175.69 |
0.29 |
0.45 |
| 2 |
A' |
3133 |
2974 |
22.62 |
111.05 |
0.35 |
0.52 |
| 3 |
A' |
2757 |
2617 |
3.95 |
94.35 |
0.23 |
0.37 |
| 4 |
A' |
1643 |
1560 |
124.43 |
12.10 |
0.23 |
0.38 |
| 5 |
A' |
1393 |
1322 |
18.74 |
6.33 |
0.07 |
0.14 |
| 6 |
A' |
1208 |
1147 |
29.92 |
11.11 |
0.51 |
0.68 |
| 7 |
A' |
936 |
888 |
53.01 |
3.48 |
0.41 |
0.58 |
| 8 |
A' |
733 |
696 |
65.34 |
3.11 |
0.13 |
0.23 |
| 9 |
A' |
429 |
407 |
19.43 |
2.64 |
0.37 |
0.54 |
| 10 |
A" |
1083 |
1029 |
1.94 |
0.47 |
0.75 |
0.86 |
| 11 |
A" |
751 |
713 |
72.08 |
2.09 |
0.75 |
0.86 |
| 12 |
A" |
402 |
381 |
32.99 |
1.77 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 8989.4 cm
-1
Scaled (by 0.9494) Zero Point Vibrational Energy (zpe) 8534.5 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.