Vibrational Frequencies calculated at wB97X-D/cc-pVTZ
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A |
3454 |
3302 |
1.13 |
|
|
|
| 2 |
A |
3191 |
3051 |
24.26 |
|
|
|
| 3 |
A |
3098 |
2962 |
32.97 |
|
|
|
| 4 |
A |
1552 |
1484 |
2.24 |
|
|
|
| 5 |
A |
1380 |
1319 |
25.75 |
|
|
|
| 6 |
A |
1319 |
1261 |
39.10 |
|
|
|
| 7 |
A |
1273 |
1217 |
13.04 |
|
|
|
| 8 |
A |
1224 |
1171 |
1.39 |
|
|
|
| 9 |
A |
1100 |
1051 |
9.35 |
|
|
|
| 10 |
A |
984 |
940 |
16.13 |
|
|
|
| 11 |
A |
940 |
898 |
33.43 |
|
|
|
| 12 |
A |
824 |
787 |
7.11 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 10169.0 cm
-1
Scaled (by 0.956) Zero Point Vibrational Energy (zpe) 9721.5 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.