Vibrational Frequencies calculated at MP2=FULL/6-31G
| Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
| 1 |
A' |
1812 |
1721 |
29.59 |
1.81 |
0.43 |
0.60 |
| 2 |
A' |
1279 |
1215 |
106.30 |
0.51 |
0.53 |
0.69 |
| 3 |
A' |
1162 |
1104 |
133.04 |
0.16 |
0.64 |
0.78 |
| 4 |
A' |
999 |
949 |
169.12 |
0.85 |
0.11 |
0.19 |
| 5 |
A' |
636 |
604 |
4.79 |
8.11 |
0.18 |
0.31 |
| 6 |
A' |
486 |
461 |
1.97 |
2.39 |
0.75 |
0.86 |
| 7 |
A' |
423 |
402 |
1.90 |
3.35 |
0.38 |
0.55 |
| 8 |
A' |
316 |
301 |
1.58 |
3.52 |
0.68 |
0.81 |
| 9 |
A' |
182 |
173 |
4.63 |
0.73 |
0.69 |
0.82 |
| 10 |
A" |
503 |
478 |
4.35 |
9.76 |
0.75 |
0.86 |
| 11 |
A" |
352 |
335 |
6.55 |
0.32 |
0.75 |
0.86 |
| 12 |
A" |
162 |
154 |
0.05 |
0.07 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 4156.0 cm
-1
Scaled (by 0.9501) Zero Point Vibrational Energy (zpe) 3948.6 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.