Vibrational Frequencies calculated at MP2=FULL/cc-pVDZ
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A' |
3264 |
3102 |
1.24 |
105.12 |
0.24 |
0.39 |
2 |
A' |
654 |
622 |
12.65 |
5.09 |
0.57 |
0.72 |
3 |
A' |
504 |
479 |
19.24 |
7.60 |
0.02 |
0.04 |
4 |
A' |
191 |
182 |
0.04 |
3.97 |
0.55 |
0.71 |
5 |
A" |
1202 |
1142 |
60.71 |
2.85 |
0.75 |
0.86 |
6 |
A" |
805 |
765 |
123.42 |
1.03 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 3310.2 cm
-1
Scaled (by 0.9504) Zero Point Vibrational Energy (zpe) 3146.0 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.