return to home page Computational Chemistry Comparison and Benchmark DataBase Release 22 (May 2022) Standard Reference Database 101 National Institute of Standards and Technology
You are here: Calculated > Energy > Optimized > Energy

All results from a given calculation for C3H4S3 (1,3-Dithiolane-2-thione)

using model chemistry: LSDA/6-31+G**

19 10 17 12 22

States and conformations

State Conformation minimum conformation conformer description state description
1 1 yes C1 1A
Energy calculated at LSDA/6-31+G**
 hartrees
Energy at 0K-1307.501834
Energy at 298.15K-1307.506965
Nuclear repulsion energy425.056712
The energy at 298.15K was derived from the energy at 0K and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at LSDA/6-31+G**
Mode Number Symmetry Frequency
(cm-1)
Scaled Frequency
(cm-1)
IR Intensities
(km mol-1)
Raman Act
4/u)
Dep P Dep U
1 A 3072 3026 1.50      
2 A 3062 3017 0.54      
3 A 3001 2956 6.71      
4 A 2999 2954 8.74      
5 A 1408 1387 4.50      
6 A 1393 1373 16.53      
7 A 1268 1249 14.57      
8 A 1229 1210 4.52      
9 A 1151 1134 22.38      
10 A 1110 1094 237.51      
11 A 1087 1070 0.75      
12 A 999 984 6.71      
13 A 934 920 4.60      
14 A 871 858 32.58      
15 A 823 810 44.09      
16 A 688 678 1.54      
17 A 687 677 0.79      
18 A 499 492 7.00      
19 A 478 471 3.53      
20 A 444 438 1.33      
21 A 386 381 0.66      
22 A 244 240 1.71      
23 A 239 236 0.32      
24 A 110 109 1.44      

Unscaled Zero Point Vibrational Energy (zpe) 14091.3 cm-1
Scaled (by 0.985) Zero Point Vibrational Energy (zpe) 13880.0 cm-1
See section III.C.1 List or set vibrational scaling factors to change the scale factors used here.
See section III.C.2 Calculate a vibrational scaling factor for a given set of molecules to determine the least squares best scaling factor.
Rotational Constants (cm-1) from geometry optimized at LSDA/6-31+G** An error occurred on the server when processing the URL. Please contact the system administrator.