S1C2
S1C3
Energy calculated at B2PLYP=FULL/aug-cc-pVTZ
| hartrees |
Energy at 0K | -169.831661 |
Energy at 298.15K | -169.835676 |
HF Energy | -169.615292 |
Nuclear repulsion energy | 70.913631 |
The energy at 298.15K was derived from the energy at 0K
and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at B2PLYP=FULL/aug-cc-pVTZ
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A' |
3846 |
3690 |
83.95 |
|
|
|
2 |
A' |
3550 |
3406 |
13.81 |
|
|
|
3 |
A' |
3074 |
2950 |
46.28 |
|
|
|
4 |
A' |
1741 |
1670 |
210.60 |
|
|
|
5 |
A' |
1416 |
1359 |
12.86 |
|
|
|
6 |
A' |
1329 |
1275 |
168.74 |
|
|
|
7 |
A' |
1192 |
1143 |
38.60 |
|
|
|
8 |
A' |
1055 |
1012 |
217.60 |
|
|
|
9 |
A' |
618 |
593 |
1.44 |
|
|
|
10 |
A" |
1038 |
996 |
1.62 |
|
|
|
11 |
A" |
831 |
798 |
65.87 |
|
|
|
12 |
A" |
417 |
400 |
64.62 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 10053.1 cm
-1
Scaled (by 0.9594) Zero Point Vibrational Energy (zpe) 9645.0 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.
Geometric Data calculated at B2PLYP=FULL/aug-cc-pVTZ
Point Group is Cs
Cartesians (Å)
Atom |
x (Å) |
y (Å) |
z (Å) |
C1 |
0.000 |
0.376 |
0.000 |
O2 |
-1.002 |
-0.533 |
0.000 |
N3 |
1.196 |
-0.015 |
0.000 |
H4 |
-0.336 |
1.413 |
0.000 |
H5 |
-1.849 |
-0.080 |
0.000 |
H6 |
1.827 |
0.778 |
0.000 |
Atom - Atom Distances (Å)
|
C1 |
O2 |
N3 |
H4 |
H5 |
H6 |
C1 | | 1.3531 | 1.2586 | 1.0903 | 1.9046 | 1.8705 |
O2 | 1.3531 | | 2.2586 | 2.0575 | 0.9609 | 3.1181 | N3 | 1.2586 | 2.2586 | | 2.0945 | 3.0462 | 1.0132 | H4 | 1.0903 | 2.0575 | 2.0945 | | 2.1261 | 2.2539 | H5 | 1.9046 | 0.9609 | 3.0462 | 2.1261 | | 3.7749 | H6 | 1.8705 | 3.1181 | 1.0132 | 2.2539 | 3.7749 | |
More geometry information
Calculated Bond Angles
atom1 |
atom2 |
atom3 |
angle |
|
atom1 |
atom2 |
atom3 |
angle |
C1 |
O2 |
H5 |
109.625 |
|
C1 |
N3 |
H6 |
110.383 |
O2 |
C1 |
N3 |
119.679 |
|
O2 |
C1 |
H4 |
114.287 |
N3 |
C1 |
H4 |
126.033 |
|
Electronic energy levels
Charges, Dipole, Quadrupole and Polarizability
Jump to
S1C1
S1C3
Energy calculated at B2PLYP=FULL/aug-cc-pVTZ
| hartrees |
Energy at 0K | -169.831661 |
Energy at 298.15K | -169.835676 |
HF Energy | -169.615292 |
Nuclear repulsion energy | 70.913631 |
The energy at 298.15K was derived from the energy at 0K
and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at B2PLYP=FULL/aug-cc-pVTZ
Geometric Data calculated at B2PLYP=FULL/aug-cc-pVTZ
Point Group is Cs
Electronic energy levels
Charges, Dipole, Quadrupole and Polarizability
Jump to
S1C1
S1C2
Energy calculated at B2PLYP=FULL/aug-cc-pVTZ
| hartrees |
Energy at 0K | -169.834393 |
Energy at 298.15K | -169.838483 |
HF Energy | -169.617793 |
Nuclear repulsion energy | 70.831150 |
The energy at 298.15K was derived from the energy at 0K
and an integrated heat capacity that used the calculated vibrational frequencies.
Vibrational Frequencies calculated at B2PLYP=FULL/aug-cc-pVTZ
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A' |
3780 |
3627 |
42.96 |
|
|
|
2 |
A' |
3469 |
3328 |
8.61 |
|
|
|
3 |
A' |
3197 |
3067 |
8.24 |
|
|
|
4 |
A' |
1711 |
1642 |
273.93 |
|
|
|
5 |
A' |
1415 |
1358 |
1.11 |
|
|
|
6 |
A' |
1346 |
1292 |
36.74 |
|
|
|
7 |
A' |
1124 |
1078 |
258.53 |
|
|
|
8 |
A' |
1076 |
1032 |
53.45 |
|
|
|
9 |
A' |
589 |
565 |
30.02 |
|
|
|
10 |
A" |
1075 |
1031 |
61.66 |
|
|
|
11 |
A" |
851 |
816 |
50.53 |
|
|
|
12 |
A" |
518 |
497 |
68.61 |
|
|
|
Unscaled Zero Point Vibrational Energy (zpe) 10074.7 cm
-1
Scaled (by 0.9594) Zero Point Vibrational Energy (zpe) 9665.7 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.
Geometric Data calculated at B2PLYP=FULL/aug-cc-pVTZ
Point Group is Cs
Cartesians (Å)
Atom |
x (Å) |
y (Å) |
z (Å) |
C1 |
0.000 |
0.440 |
0.000 |
O2 |
-1.099 |
-0.355 |
0.000 |
N3 |
1.222 |
0.125 |
0.000 |
H4 |
-0.302 |
1.480 |
0.000 |
H5 |
-0.829 |
-1.281 |
0.000 |
H6 |
1.375 |
-0.882 |
0.000 |
Atom - Atom Distances (Å)
|
C1 |
O2 |
N3 |
H4 |
H5 |
H6 |
C1 | | 1.3567 | 1.2615 | 1.0821 | 1.9106 | 1.9076 |
O2 | 1.3567 | | 2.3699 | 1.9999 | 0.9651 | 2.5297 | N3 | 1.2615 | 2.3699 | | 2.0385 | 2.4862 | 1.0189 | H4 | 1.0821 | 1.9999 | 2.0385 | | 2.8104 | 2.8964 | H5 | 1.9106 | 0.9651 | 2.4862 | 2.8104 | | 2.2394 | H6 | 1.9076 | 2.5297 | 1.0189 | 2.8964 | 2.2394 | |
More geometry information
Calculated Bond Angles
atom1 |
atom2 |
atom3 |
angle |
|
atom1 |
atom2 |
atom3 |
angle |
C1 |
O2 |
H5 |
109.595 |
|
C1 |
N3 |
H6 |
113.122 |
O2 |
C1 |
N3 |
129.656 |
|
O2 |
C1 |
H4 |
109.665 |
N3 |
C1 |
H4 |
120.678 |
|
Electronic energy levels