Vibrational Frequencies calculated at B2PLYP=FULLultrafine/daug-cc-pVDZ
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A |
3817 |
3817 |
49.68 |
74.99 |
0.17 |
0.30 |
2 |
A |
3179 |
3179 |
24.68 |
59.27 |
0.52 |
0.69 |
3 |
A |
3082 |
3082 |
51.10 |
117.45 |
0.09 |
0.16 |
4 |
A |
1516 |
1516 |
1.99 |
3.66 |
0.75 |
0.86 |
5 |
A |
1429 |
1429 |
30.49 |
1.80 |
0.69 |
0.81 |
6 |
A |
1391 |
1391 |
11.82 |
2.29 |
0.45 |
0.62 |
7 |
A |
1254 |
1254 |
7.21 |
3.24 |
0.56 |
0.72 |
8 |
A |
1137 |
1137 |
138.06 |
5.68 |
0.11 |
0.20 |
9 |
A |
1064 |
1064 |
81.89 |
0.79 |
0.18 |
0.30 |
10 |
A |
971 |
971 |
175.67 |
5.04 |
0.36 |
0.53 |
11 |
A |
530 |
530 |
28.32 |
1.26 |
0.45 |
0.62 |
12 |
A |
384 |
384 |
110.19 |
1.72 |
0.71 |
0.83 |
Unscaled Zero Point Vibrational Energy (zpe) 9878.1 cm
-1
Scaled (by 1) Zero Point Vibrational Energy (zpe) 9878.1 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.