Vibrational Frequencies calculated at B2PLYP=FULLultrafine/Def2TZVPP
Mode Number |
Symmetry |
Frequency (cm-1) |
Scaled Frequency (cm-1) |
IR Intensities (km mol-1) |
Raman Act (Å4/u) |
Dep P |
Dep U |
1 |
A' |
3259 |
3259 |
1.37 |
82.70 |
0.59 |
0.74 |
2 |
A' |
3226 |
3226 |
3.79 |
118.26 |
0.27 |
0.43 |
3 |
A' |
3162 |
3162 |
0.76 |
154.96 |
0.18 |
0.31 |
4 |
A' |
1645 |
1645 |
38.26 |
15.48 |
0.06 |
0.11 |
5 |
A' |
1422 |
1422 |
12.74 |
20.82 |
0.37 |
0.54 |
6 |
A' |
1275 |
1275 |
47.54 |
13.04 |
0.23 |
0.37 |
7 |
A' |
1015 |
1015 |
5.29 |
2.62 |
0.75 |
0.86 |
8 |
A' |
552 |
552 |
11.08 |
6.23 |
0.12 |
0.22 |
9 |
A' |
312 |
312 |
0.14 |
8.12 |
0.39 |
0.56 |
10 |
A" |
993 |
993 |
35.65 |
0.01 |
0.75 |
0.86 |
11 |
A" |
948 |
948 |
21.75 |
0.68 |
0.75 |
0.86 |
12 |
A" |
564 |
564 |
19.24 |
1.20 |
0.75 |
0.86 |
Unscaled Zero Point Vibrational Energy (zpe) 9187.1 cm
-1
Scaled (by 1) Zero Point Vibrational Energy (zpe) 9187.1 cm
-1
See section
III.C.1 List or set vibrational scaling factors
to change the scale factors used here.
See section
III.C.2
Calculate a vibrational scaling factor for a given set of molecules
to determine the least squares best scaling factor.