Calculated Ionization Energy for CH3OO (methylperoxy radical)

20 09 09 14 00
Please note! These calculated ionizataion energies have the vibrational zero-point energy (zpe) included, but the zpe has NOT been scaled. Click on an entry for more details, including the ionization energy with a scaled zpe.
Original data displayed. Press to display differences.
Differences displayed. Press to display original data.

Ionization Energies in eV
Methods with predefined basis sets
composite G2 10.400
G3 10.482
G4 10.401
CBS-Q 10.500

Ionization Energies in eV
Methods with standard basis sets
3-21G 3-21G* 6-31G* 6-31+G** 6-311G** 6-311+G(3df,2p) TZVP cc-pVDZ cc-pVTZ aug-cc-pVTZ daug-cc-pVTZ
hartree fock HF     10.685       10.657       10.556
density functional B3LYP     10.615       10.741   10.699    
M06-2X   11.115                  
TPSSh     10.476                
wB97X-D   10.941 10.570 10.733 10.636   10.658 10.733 10.553 10.595  
B97D3 10.472   10.189 10.403 10.291 10.341 10.366   10.267 10.340  
3-21G 3-21G* 6-31G* 6-31+G** 6-311G** 6-311+G(3df,2p) TZVP cc-pVDZ cc-pVTZ aug-cc-pVTZ daug-cc-pVTZ
Moller Plesset perturbation MP2     9.701       9.816   9.962    
3-21G 3-21G* 6-31G* 6-31+G** 6-311G** 6-311+G(3df,2p) TZVP cc-pVDZ cc-pVTZ aug-cc-pVTZ daug-cc-pVTZ

Ionization Energies in eV
Methods with effective core potentials (select basis sets)
CEP-31G CEP-31G* CEP-121G CEP-121G* LANL2DZ SDD cc-pVTZ-PP aug-cc-pVTZ-PP Def2TZVPP
hartree fock HF                 10.553
density functional B3LYP                 10.672
PBEPBE                 10.264
Moller Plesset perturbation MP2                 9.954
For descriptions of the methods (AM1, HF, MP2, ...) and basis sets (3-21G, 3-21G*, 6-31G, ...) see the glossary in section I.C. Predefined means the basis set used is determined by the method.