return to home page Computational Chemistry Comparison and Benchmark DataBase Release 22 (May 2022) Standard Reference Database 101 National Institute of Standards and Technology
You are here: Resources > Info on Results > Calculations Done > One molecule

Completed calculations for CuCN (Copper cyanide)

Methods and basis sets for which an energy has been calculated. "e" indicates just an energy has been calculated. "o" indicates an optimized geometry. "v" indicates vibrational frequencies. "s" followed by a number indicates completed calculations for different states (for example s1ov). "c" followed by a number indicates completed calculations for different conformations (for example c2ov).
See the Calculated Energies page (section III.A.1) for more calculated properties.
Methods with predefined basis sets
composite G2 s1e s2e
CBS-Q s1e s2e

Methods with standard basis sets
3-21G 3-21G* 6-31G* 6-31+G** 6-311G** 6-311+G(3df,2p) TZVP cc-pVDZ cc-pVTZ cc-pVQZ aug-cc-pVDZ aug-cc-pVTZ aug-cc-pVQZ daug-cc-pVTZ
hartree fock HF                           s1ov s2ov
density functional BLYP     s1o s2o                      
M06-2X   s1ov s2ov       s1ov s2ov                
wB97X-D   s1ov s2ov s1o s2ov s1ov s2ov s1ov s2ov   s1ov s2ov s1ov s2ov s1ov s2ov     s1ov s2ov    
B97D3 s1ov s2ov   s1o s2o s1ov s2o s1ov s2ov s1ov s2o s1ov s2ov   s1ov s2o     s1ov s2o   s1ov s2o
Moller Plesset perturbation B2PLYP=FULLultrafine     s1o s2o         s1ov s2ov s1ov s2ov     s1ov s2ov    
Quadratic configuration interaction QCISD(T)=FULL     s1o s2o s1o       s1o s2o s1o s2o s1o s2dnf s1o s2o s1o s2o s1o s2o  
3-21G 3-21G* 6-31G* 6-31+G** 6-311G** 6-311+G(3df,2p) TZVP cc-pVDZ cc-pVTZ cc-pVQZ aug-cc-pVDZ aug-cc-pVTZ aug-cc-pVQZ daug-cc-pVTZ

Methods with effective core potentials (select basis sets)
CEP-31G CEP-31G* CEP-121G CEP-121G* LANL2DZ SDD cc-pVTZ-PP aug-cc-pVTZ-PP Def2TZVPP
hartree fock HF                 s1ov s2ov
density functional B3LYP                 s1ov s2ov
PBEPBE                 s1ov s2ov
Moller Plesset perturbation MP2                 s1ov s2ov

Barriers to internal rotation or inversion


Methods with predefined basis sets

Methods with standard basis sets
6-31G* cc-pVTZ aug-cc-pVTZ
hartree fock HF s1c1t1 s1c1t1 s1c1t1
density functional B3LYP s1c1t1 s1c1t1 s1c1t1
PBEPBEultrafine s1c1t1 s1c1t1 s1c1t1
Moller Plesset perturbation MP2=FULL s1c1t1 s1c1t1 s1c1t1
Coupled Cluster CCSD s1c1t1 s1c1t1 s1c1t1
6-31G* cc-pVTZ aug-cc-pVTZ
For descriptions of the methods (AM1, HF, MP2, ...) and basis sets (3-21G, 3-21G*, 6-31G, ...) see the glossary in section I.C. Predefined means the basis set used is determined by the method.